Learn More
Cytiva HiTrap™ MabSelect™ Prepacked Columns
Use these columns in small-scale MAb purification in a continuous bioprocess. Cytiva Life Sciences™ HiTrap™ MabSelect™ Prepacked Columns for fast purification of monoclonal antibodies (Mabs) from large sample volumes
Marque: Cytiva 28-4082-55
Code nomenclature Nacres: NA.56
Informations supplémentaires : Poids : 0.08700kg
Description
Prepacked HiTrap columns for process development, screening of purification conditions, and small-scale purification of Mabs. MabSelect media are suited for the high flowrates and pressures required when scaling up.
- Oriented coupling of recombinant Protein A ligand to the agarose matrix via an engineered C-terminal cysteine increases IgG binding capacity over other protein A media
- High capacity, low ligand leakage, and high-flow base matrix allow purification of Mabs at process scale
- Fewer regulatory concerns due to the total absence of mammalian culture in the ligand production and purification
- Designed for use with a syringe, a peristaltic pump, or a chromatography system
MabSelect
- Allows at least five times higher flowrates than conventional cross-linked agarose of similar porosity
- Recombinant Protein A ligand promotes specificity of binding to Fc region of IgG; permits one-step purification
- Same recombinant protein A ligand as MabSelect, but with a smaller particle size and greater porosity, for increased dynamic binding capacity
- Allows binding from samples with high expression levels of the monoclonal antibody
- Lowers overall production cost due to the possibility of processing concentrated feedstocks in fewer batches
- Akali-tolerant protein A-derived ligand allows the use of up to 0.5M NaOH for cleaning-in-place (CIP)
- Permits significant cost savings and extension of cycles in regular production
Spécification
∼30 mg/mL Human lgG at 2.4 min. residence time | |
0.62 in. | |
5 mL | |
5 mL | |
4°C to 30°C |
1.6 cm | |
<20mL/min. | |
For fast purification of monoclonal antibodies from large sample volumes, Protein Purification | |
20% Ethanol | |
Each |
Sécurité et traitement
- HiTrap MabSelect, 5 ml
Mention d'avertissement
- Attention
Catégorie de danger
- Liquide inflammable Catégorie 3
Mention de danger
- H226-Liquide et vapeurs inflammables.
Conseils de prudence
- P280-Porter des gants de protection/des vêtements de protection/un équipement de protection des yeux/ du visage.
- P210-Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
- P241-Utiliser du matériel électrique/de ventilation/d'éclairage/ antidéflagrant.
- P303+P361+P353-EN CAS DE CONTACT AVEC LA PEAU (ou les cheveux): Enlever immédiatement tous les vêtements contaminés. Rincer la peau à l'eau/Se doucher.
- P235-Tenir au frais.
- P501b-Éliminer le contenu/récipient conformément à la réglementation locale/régionale/nationale/internationale.
Informations supplémentaires
- MIXTURE LIST-Contient: Ethanol