Filtered Search Results
Cytiva Whatman™ Qualitative Filter Paper: Grade 1 Circles
Covers a wide range of laboratory applications and is frequently used for clarifying liquids. Whatman™ Qualitative Filter Paper: Grade 1 Circles are widely used standard grade filter papers for routine applications with medium retention and flow rates.
| Thickness (Metric) | 180 μm |
|---|---|
| Flow Rate | 57mL/min. (water) |
| Particle Retention | >11 μm |
| Basis Weight | 87 g/m2 |
| Format | Disc |
| Airflow Rate | 13sec./100mL/sq. in. |
| Grade | Grade 1 |
| Material | Cellulose |
| Porosity | Medium |
| Filtration Speed | 150 sec. |
| For Use With (Application) | A widely used standard grade filter paper for routine applications with medium retention and flow rate. It covers a wide range of laboratory applications and is frequently used for clarifying liquids. |
Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls
Use this versatile nitrocellulose membrane for excellent binding affinity for small proteins and peptides, as well as nucleic acids. Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls offer excellent sensitivity, resolution, and low background.
| Format | Roll |
|---|---|
| Length (Metric) | 4 m |
| Material | 100% Pure Nitrocellulose |
| For Use With (Application) | Western blots, dot-blot assays, and other protein or nucleic acid methods |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C
Combines fine particle retention with good flow rate. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C are ideal for the collection of suspended solids in potable water, natural and industrial wastes.
| Thickness (Metric) | 260 μm |
|---|---|
| Flow Rate | 10.5 sec./100 mL |
| Particle Retention | 1.2 μm |
| Temperature (English) Max. | 932°F |
| Basis Weight | 53 g/m2 |
| Shape | Circle |
| Format | Disc |
| Description | GE’s Whatman filter paper Grade GF/C glass filters offer a good flow rate and loading capacity that support total suspended solids analysis. |
| Thickness (English) | 0.01 in. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/C |
| Material | Borosilicate Glass |
| Waterflow Rate | 105 mL/min |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A
Combines high loading capacity with fine particle retention. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A are ideal for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.
| Particle Retention | 1.6 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | GE’s Whatman Grade GF/A glass microfiber filters feature fine retention. GF/A filters are suitable for water quality parameter measurement and air filtration applications. |
| Temperature (Metric) Max | 500°C |
| Quantity | 100 Pieces |
| Grade | Grade GF/A |
| Material | Borosilicate Glass |
| For Use With (Application) | Used for high-efficiency general purpose laboratory filtration, including water pollution monitoring of effluents, for filtration of water, foodstuff analyses, protein filtration, and radioimmunoassay of weak β emitters. |
| Thickness (Metric) | 260 μm |
| Flow Rate | 13 sec./100mL |
| Type | Fine Retention Filter |
| Format | Disc |
| Thickness (English) | 0.01 in. |
| Waterflow Rate | 143 mL/min |
Cytiva Amersham™ ECL Select™ Western Blotting Detection Reagent
Use as a high sensitivity reagent for chemiluminescent Western blotting detection. Cytiva Life Sciences™ Amersham™ ECL Select™ Western Blotting Detection Reagent provides highly intense signal output, for detection of medium to very low protein levels.
Cytiva Amersham™ Hybond™ P 0.45μm PVDF Membrane
Use for chemiluminescent and fluorescent detection methods for proteins of > Mr 20 000. Cytiva Life Sciences™ Amersham™ Hybond™ P 0.45μm PVDF Membrane is a 0.45 μm pore size hydrophobic membrane, with high physical strength, highly suitable for stripping and reprobing.
| Pore Size | 0.45 μm |
|---|
Cytiva Whatman™ 3MM Chr Chromatography Paper
Manufactured entirely from high-quality cotton linters with no additives and tested specifically for chromatographic techniques. Whatman™ Grade 3MM Chr Chromatography Paper ensures the wicking capability and uniformity of capillary action that are important in chemical separations.
| Flow Rate | 130 mm/30 min. |
|---|---|
| Description | 0.34 mm Whatman medium thickness 3 MM Chr paper |
| Material | Cellulose |
| Grade | 3 MM Chr |
| For Use With (Application) | For Electrophoresis, General Chromatography, and Blotting AppliCatIons |
| Finish | Smooth |
| Film Thickness | 0.34 mm |
Cytiva Whatman™ pH Indicator Papers, CF Strips
Provides an extremely clear and accurate visual pH value using four different segments of dye-impregnated indicator papers. Whatman™ pH Indicator Papers, CF Strips use dyes that are chemically bonded to the paper and cannot be leached into solution.
| Includes | Plastic supports, paper segments on each strip, complementary indicator charts |
|---|---|
| Type | pH Test Strip, Color Bonded |
| Format | Strip |
| Length (Metric) | 80 mm |
| Quantity | 100 Pack |
| Width (Metric) | 6 mm |
| Dimensions (L x W) | 80 x 6 mm |
Cytiva Amersham™ Protran™ Premium NC Nitrocellulose Membranes: Rolls
Use for the best results with fluorescence Western blotting detection applications. Cytiva Life Sciences™ Amersham™ Protran™ Premium NC Nitrocellulose Membranes: Rolls offer excellent sensitivity, resolution, and low background.
| Format | Roll |
|---|---|
| Length (Metric) | 4 m |
| Material | 100% Pure Nitrocellulose |
| For Use With (Application) | Western blots, dot-blot assays, and other protein or nucleic acid methods |
Cytiva Ficoll-Paque™ PREMIUM, 1.078g/mL
For density gradient centrifugation preparations of mononuclear cells from peripheral blood, bone marrow and umbilical cord blood. Cytiva Life Sciences™ Ficoll-Paque™ PREMIUM is a range of sterile, ready-to-use density gradient media manufactured under a Quality Management System.
| Content And Storage | 4–30°C |
|---|---|
| Form | Liquid |
| Product Type | Centrifugation Media |
| Color | Colorless to Slightly Yellow |
| Endotoxin Level | < 0.12 EU/mL |
| Shelf Life | 3 years |
| For Use With (Application) | Optimized for the isolation of mononuclear cells from human peripheral blood, bone marrow, and umbilical cord blood. |
| Sterility | Sterile |
| Density | 1.078 g/mL |
| Osmolality | 288-310 mOsm/kg |
Cytiva Whatman™ Quantitative Filter Paper: Grade 40 Circles
Supports accurate analysis in applications sensitive to very low levels of background contamination. Whatman™ Quantitative Filter Paper: Grade 40 Circles are additionally useful in gravimetric analysis where ash content might affect weight measurements of combusted samples.
| Pore Size | 8 μm |
|---|---|
| Particle Retention | 8 μm |
| Airflow Rate | 21 s/100 mL/in2 |
| Quantity | 100 Pk. |
| Grade | Grade 40 |
| Material | Cotton Linters |
| Filtration Speed | ASTM, 75 seconds; Herzberg, 340 seconds |
| For Use With (Application) | Designed for gravimetric analysis and the preparation of samples for instrumental analysis.Gravimetric analysis for numerous components in cements, clays, iron, and steel products.As a primary filter for separating solid matter from aqueous extracts in |
| Thickness (Metric) | 210 μm |
| Flow Rate | Medium |
| Type | Quantitative Filter Paper |
| Format | Disc |
| Filter Type | Ashless |
| Porosity | Medium |
Cytiva Percoll™ Centrifugation Media
For separation of cells, subcellular particles, and larger viruses (down to approx. 70S) under gentle conditions that preserve viability and morphological integrity. Cytiva™ Percoll™ Centrifugation Media Percoll is composed of colloidal silica coated with polyvinylpyrrolidone (PVP).
| Viscosity | 15cP |
|---|---|
| Content And Storage | 4–30°C |
| Form | Liquid |
| Product Type | Centrifugation Media |
| Color | Colorless to Slightly Yellow |
| pH | 8.5 to 9.5 |
| Shelf Life | 5 years |
| For Use With (Application) | Cell Isolation |
| Density | 1.135 g/mL |
| Osmolality | < 25 mOsm/kg |
Cytiva HyClone™ RPMI 1640 Media
Designed to support cell culture growth and biomanufacturing processes.
| Content And Storage | 2° to 8°C, away from light |
|---|---|
| Sterilization Method | 0.1 μm Sterile-filtered |
| Product Type | RPMI 1640 |
| Form | Liquid |
| Certifications/Compliance | ISO 9001:2000 |
Cytiva Whatman™ Quantitative Filter Paper: Grade 42 Circles
Filters and retains extremely small particles. Whatman™ Quantitative Filter Paper: Grade 42 Circles are suitable for processes that require ashing.
| Thickness (Metric) | 200 μm |
|---|---|
| Pore Size | 2.5 μm |
| Flow Rate | Slow |
| Type | Quantitative Filter Paper |
| Format | Disc |
| Airflow Rate | 96 s/100 mL/in2 |
| Quantity | 100 Pk. |
| Grade | Grade 42 |
| Material | Cotton Linters |
| Filter Type | Ashless |
| Porosity | Fine |
| Filtration Speed | 1870 sec. |
| For Use With (Application) | Designed for gravimetric analysis and the preparation of samples for instrumental analysis.For critical gravimetric analysis with the finest particle retention. |