Thermo Scientific™ UltiMate™ 3000 ECD-3000RS Electrochemical Detector

Product Code. 16484499 Shop All Thermo Scientific Products
Change view
Click to view available options
Detector Type:
Electrochemical (ECD)
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Product Code. Detector Type
16484499 Electrochemical (ECD)
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 options
This item is not returnable. View return policy
Product Code. 16484499 Supplier Thermo Scientific™ Supplier No. 50700010
 Restricted Item

This item requires a price update prior to being ordered.

Request a Price for this item here.

missing translation for 'validMainframeMsg'

This item is not returnable. View return policy

Need gradient-compatible electrochemical detection? This detector offers sensitivity and selectivity with a choice of cells to match your application.

Achieve the lowest possible detection limits for oxidizable and reducible compounds. The Thermo Scientific™ Dionex™ UltiMate™ 3000 ECD-3000RS Electrochemical Detector offers easy, direct measurement to femtogram levels in very limited sample volumes with minimal preparation. It readily eliminates matrix interferences to enhance selectivity. Users have a choice of both coulometric and amperometric sensors for extremely selective analyses using microbore to normal bore columns for both HPLC and UHPLC. This is the only electrochemical detector compatible with gradient chromatography.

Recommended Use
Electrochemical detection can be used in a range of applications. The sensitivity of the Dionex UltiMate 3000 ECD-3000RS Electrochemical Detector excels in isocratic mode for neurochemical measurements in brain research. In pharmaceutical applications, it is a simple and robust platform for stability testing and identification of potential metabolites. Its high selectivity makes it ideal for characterization of complex samples, such as natural products, biological tissues, and fluids.

Performance

  • Ultralow peak dispersion and high data acquisition rates for conventional or fast, high-resolution UHPLC chromatography.
  • Simultaneously measures both low and high levels of analytes without losing data to peak overranging with Auto-Ranging feature
  • Unique compatibility with aggressive gradients for method flexibility

Ease of Use

  • Easily expand to multiple (up to four) independent sensors for unrivaled flexibility.
  • SmartChip™ Intelligence provides automatic instrument configuration with optimized control of an attached electrochemical sensor, automatic sensor recognition, event logging, and electrode protection.
  • Fluidic components can be accessed and exchanged without any tools.
  • Front panel display provides easy monitoring of detector status to maximize up time.

SmartChip technology delivers simple, flexible, and routine maintenance-free operation:

  • Plug-and-play electrochemical cells to eliminate lengthy cable connections and noise
  • Choice of coulometric and amperometric designs to match your application
  • Amperometric sensors available with a variety of working electrode materials, including boron-doped diamond for measurement of thiols, thioethers, and other sulfur-containing compounds
  • Maintenance-free, solid state reference electrodes

Specifications

Automated Start-Up Functions Automatic Detection Parameters Configuration by Thermo Scientific Dionex Chromeleon Software Through SmartChip EC Cell Recognition
Autozero External Software Controlled
Certifications/Compliance UL, CUL, CE and cTUV
Description ECD-3000 RS Electrochemical Detector
Data Collection Rate 200 Hz Max.
Detection Mode DC/PAD (Up to 8 Channels)
Detector Type Electrochemical (ECD)
Type Electrochemical Detector
Display Multi-Line LCD Display Indicates Active System Parameters, Three LEDs for Status Monitoring
Filter Advanced Multi-Level Digital Filtering
GLP Features Automatic Instrument Qualification (AutoQ), System Wellness, and Qualification Monitoring with Chromeleon Software and Cell ID Chips
Noise <750 fA (0.75 pA) with 500 MΩ/0.47 μF Cell Simulator (DC Mode)
Output Range ± 3300 mV Settable in 1 mV Steps (Acceptable Range Determined by Sensor Type)
PC Connection All Detector Functions Controllable Via USB 2.0 Through Chromeleon Data System (Cable Provided)
Signal Range 10 pA to 100 μA
User Input TTL (3): Cells OFF, Autozero and External Start
Length (Metric) 51 cm
Width (Metric) 42 cm
Height (Metric) 19 cm
Weight (Metric) 12.5 kg
Electrical Requirements 85-260 V 50/60 Hz
Voltage 85 to 260 V
Frequency 50/60 Hz
Show More Show Less